K8AK/K8DS Series Measuring and Monitoring Relays
K8AK-AS Single-phase Current Relay
-
Monitor for overcurrents or undercurrents.
-
Use commercially available CTs (CT current on secondary side: 0 to 1 A or 0 to 5 A).
-
Manual resetting and automatically resetting supported by one Relay.
-
Startup lock and operating time can be set separately.
-
One SPDT output relay, 5 A at 250 VAC (resistive load).
-
Output relay can be switched between normally open and normally closed.
-
Output status can be monitored using LED indicator.
-
Inputs are isolated from the power supply.
K8AK-AW Single-phase Overcurrent/Undercurrent Relays
-
Monitor for overcurrents and undercurrents simultaneously.
-
Separate settings and outputs supported for overcurrents and undercurrents.
-
Use commercially available CTs (CT current on secondary side: 0 to 1 A or 0 to 5 A).
-
Manual resetting and automatically resetting supported by one Relay.
-
Startup lock and operating time can be set separately.
-
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
-
Output status can be monitored using LED indicator.
-
Inputs are isolated from the power supply.
K8AK-VS Single-phase Voltage Relay
-
Monitor for overvoltages or undervoltages.
-
Manual resetting and automatically resetting supported by one Relay.
-
One SPDT output relay, 5 A at 250 VAC (resistive load).
-
Output relay can be switched between normally open and normally closed.
-
Process control signal (0 to 10 V) and current splitter input supported.
-
Output status can be monitored using LED indicator.
-
Input frequency of 40 to 500 Hz supported.
-
Inputs are isolated from the power supply.
K8AK-VW Single-phase Overvoltage/Undervoltage Relays
-
Monitor for overvoltages and undervoltages simultaneously.
-
Separate settings and outputs supported for overvoltages and undervoltages.
-
Manual resetting and automatically resetting supported by one Relay.
-
Pre-alarm Monitoring Mode.
-
Two SPDT output relays, 5 A at 250 VAC (resistive load).
-
Process control signal (0 to 10 V) and current splitter input supported.
-
Output status can be monitored using LED indicator.
-
Input frequency of 40 to 500 Hz supported.
-
Inputs are isolated from the power supply.
K8DS-PH Phase-sequence Phase-loss Relay
-
Lineup includes a 17.5-mm slim, compact model.
-
Greater resistance to inverter noise.
-
Distinguishes between positive phases, reversed phases, and phase loss when power is turned ON.
-
Supports phase loss detection when the motor is operating.
-
Output status can be monitored using LED indicator.
-
Ideal to prevent reverse operation of motors.
K8AK-PH Phase-sequence Phase-loss Relay
-
Greater resistance to inverter noise.
-
Distinguishes between positive phases, reversed phases, and phase loss when power is turned ON.
-
5 A (resistive load) at 250 VAC, DPDT x 1.
-
Output status can be monitored using LED indicator.
-
Ideal to prevent reverse operation of motors.
K8AK-PW Three-phase Voltage Relay
-
Greater resistance to inverter noise.
-
Monitor overvoltages and undervoltages for three-phase 3-wire or 4-wire power supplies.
-
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
-
Two SPDT output relays, 5 A at 250 VAC (resistive load).
-
Separate outputs possible for overvoltages and undervoltages.
-
World-wide power specifications supported by one Unit (switchable using DIP switch).
-
Relay status can be monitored using LED indicator.
K8AK-PM Three-phase Phase-sequence Phase-loss Relay
-
Greater resistance to inverter noise.
-
Monitor overvoltages, undervoltages, phase sequence, and phase loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
-
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
-
Two SPDT output relays, 5 A at 250 VAC (resistive load).
-
Output overvoltages and undervoltages using separate relays.
-
World-wide power specifications supported by one Unit (switchable).
-
Output status can be monitored using LED indicator.
K8AK-PA Three-phase Asymmetry and Phase-sequence Phase-loss Relay
-
Greater resistance to inverter noise.
-
Monitor voltage asymmetry, phase sequence, and phase loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
-
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
-
One SPDT output relay, 5 A at 250 VAC (resistive load).
-
World-wide power specifications supported by one Unit (switchable).
-
Relay status can be monitored using LED indicator.
K8AK-TH Temperature Monitoring Relay
-
Excessive temperature increases can be prevented and abnormal temperatures can be monitored.
-
Temperature monitoring in slim design with a width of just 22.5 mm.
-
Rotary switches simplifies temperature settings.
-
Universal-input support for thermocouple or platinum resistance thermometer sensor input.
-
Change the output relay between normally open and normally closed operation.
-
Alarm status identification with LED indicator.
-
Self-holding output.
K8AK-LS Conductive Level Controller
-
Self-holding ON or OFF outputs can be selected using self-holding circuit.
-
Sensitivity adjustment of operating resistance from 10 to 100 kΩ for application to a wide range of liquids.
-
Prevents chattering of relay contacts that occurs with ripples.
-
Easy wiring with ferrules.
-
Use 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 ferrules.
-
Applicable as a floatless switch.
Source: http://www.omron-ap.com.my/product_info/K8AK/index.asp